Abstract We have developed a monochromatic synchrotron radiationexcited system for two-dimensional mapping of x-ray fluorescence evoked from heavy elementloaded microspheres, which can evaluate myocardial blood flow in small contiguous regions with a small methodological error: 10.8±2.4% of the average of difference of the dual flow for 7- to 10-mg myocardial tissue (4 dogs). The fractal D value obtained from the slope of the log relative dispersionlog mass plot was 1.21±0.08 for a voxel size of 7 to 1260 mg (5 dogs) and that for a voxel size of 2.5 to 40 mg (1.12±0.06) was smaller than that for a voxel size of 40 to 1280 mg (1.25±0.14, P<.05, ANOVA, 4 dogs). The distancecorrelation coefficient relation for paired myocardial regions was attenuated (correlation analysis), and the correlation coefficients between the original grouping and the two aggregates of the adjacent regions were dissociated (extended correlation analysis) under reduction of coronary perfusion pressure (6 dogs). Suppression of myocardial contraction with lidocaine (3 dogs) and vasodilation with adenosine partly improved the distancecorrelation coefficient relation under reduced coronary perfusion pressure. Thus, an x-ray fluorescence system designed for precise flow measurement shows that the fractal nature of local flow distribution can be extended into regions smaller than previously reported, that in these regions the flow becomes more homogeneous, and that the self similarity and continuity of local flow are attenuated by the reduction of coronary perfusion pressure and improved by contractile suppression and coronary vasodilation.
Key Words: microsphere myocardial ischemia microcirculation fractal analysis
This article has been cited by other articles:
![]() |
B. Kaimovitz, Y. Huo, Y. Lanir, and G. S. Kassab Diameter asymmetry of porcine coronary arterial trees: structural and functional implications Am J Physiol Heart Circ Physiol, February 1, 2008; 294(2): H714 - H723. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. K. M. Decking, V. M. Pai, E. Bennett, J. L. Taylor, C. D. Fingas, K. Zanger, H. Wen, and R. S. Balaban High-resolution imaging reveals a limit in spatial resolution of blood flow measurements by microspheres Am J Physiol Heart Circ Physiol, September 1, 2004; 287(3): H1132 - H1140. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Karch, F. Neumann, B. K. Podesser, M. Neumann, P. Szawlowski, and W. Schreiner Fractal Properties of Perfusion Heterogeneity in Optimized Arterial Trees: A Model Study J. Gen. Physiol., August 25, 2003; 122(3): 307 - 322. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. I. E. Hoffman and W. M. Chilian Brief commentary on coronary wave-intensity analysis J Appl Physiol, October 1, 2000; 89(4): 1633 - 1635. [Full Text] [PDF] |
||||
![]() |
E. Tanaka, N. Hattan, K. Ando, H. Ueno, Y. Sugio, M. U. Mohammed, S. A. Voltchikhina, and H. Mori Amelioration of microvascular myocardial ischemia by gene transfer of vascular endothelial growth factor in rabbits J. Thorac. Cardiovasc. Surg., October 1, 2000; 120(4): 720 - 728. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Hattan, K. Ban, E. Tanaka, S. Abe, T. Sekka, Y. Sugio, M. U. Mohammed, E. Sato, Y. Shinozai, Y. Onishi, et al. Transmyocardial revascularization aggravates myocardial ischemia around the channels in the immediate phase Am J Physiol Heart Circ Physiol, September 1, 2000; 279(3): H1392 - H1396. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kleen, O. Habler, F. Meisner, G. Kemming, A. Pape, and K. Messmer Effects of primary resuscitation from shock on distribution of myocardial blood flow J Appl Physiol, February 1, 2000; 88(2): 373 - 385. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Nakajima, N. Akizuki, Y. Kimura, H. Kohguchi, A. Tanaka, M. Chujo, N. Hattan, Y. Shinozaki, A. Iida, S. Handa, et al. Intramyocardial vascular volume distribution studied by synchrotron radiation-excited X-ray fluorescence Am J Physiol Heart Circ Physiol, December 1, 1999; 277(6): H2353 - H2362. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. G. M. van Beek, H. G. J. van Mil, R. B. King, F. J. J. de Kanter, D. J. C. Alders, and J. Bussemaker A 13C NMR double-labeling method to quantitate local myocardial O2 consumption using frozen tissue samples Am J Physiol Heart Circ Physiol, October 1, 1999; 277(4): H1630 - H1640. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Matsumoto, J. Ebata, H. Tachibana, M. Goto, and F. Kajiya Transmural microcirculatory blood flow distribution in right and left ventricular free walls of rabbits Am J Physiol Heart Circ Physiol, July 1, 1999; 277(1): H183 - H191. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Tanaka, H. Mori, E. Tanaka, M. U. Mohammed, Y. Tanaka, T. Sekka, K. Ito, Y. Shinozaki, K. Hyodo, M. Ando, et al. Branching patterns of intramural coronary vessels determined by microangiography using synchrotron radiation Am J Physiol Heart Circ Physiol, June 1, 1999; 276(6): H2262 - H2267. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kleen, M. Welte, P. Lackermeier, O. Habler, G. Kemming, and K. Messmer Myocardial blood flow heterogeneity in shock and small-volume resuscitation in pigs with coronary stenosis J Appl Physiol, December 1, 1997; 83(6): 1832 - 1841. [Abstract] [Full Text] [PDF] |
||||
|
Circulation Research Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1995 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |