Clinical Research |
From the Department of Cardiology and Endocrinology (L.H.M.), Frederiksberg University Hospital, Copenhagen, Denmark; Center for Heart Failure Research (L.H.M., G.C., D.A.), University of Oslo, Norway; Institute for Experimental Medical Research (G.C., I.H., Z.G.), Ullevål University Hospital, Oslo, Norway; Hormone Laboratory (T.L.), Aker University Hospital, Oslo, Norway; HeartDrug Research Laboratories (V.L.S.), Towson, Md; Duke University Medical Center (C.B.G., J.H.A.), Durham, NC; Division of Cardiology and Laboratory Medicine (A.S.J.), Mayo Clinic and Graduate Medical School, Rochester, Minn; Division of Cardiology (J.E.V.E.), Johns Hopkins University, Baltimore, Md; and Division of Cardiology (D.A.), Aker University Hospital, University of Oslo, Norway.
Correspondence to Lene Helleskov Madsen, MD, Frederiksberg University Hospital, Department of Cardiology and Endocrinology, Ndr. Fasanvej 57-59, 2000 Frederiksberg, Denmark. E-mail lhm{at}dadlnet.dk
| Abstract |
|---|
|
|
|---|
Key Words: myocardial infarction troponin troponin degradation diagnostics
| Introduction |
|---|
|
|
|---|
| Materials and Methods |
|---|
|
|
|---|
Biochemical Testing
Platelet-poor plasma was collected from all patients at intervals stated above and assayed immediately for routine biochemistry tests including creatine kinase (CK) and its MB isoenzyme (CK-MB). The diagnosis of AMI was confirmed by a typical time profile observed with at least a doubling of baseline values for at least 1 of the assays, as defined in the ASSENT-2 study. Regarding further analysis processing and handling of blood samples were standardized and serum aliquoted and frozen at 80°C until analysis. Samples were thawed only once before immunoblotting. Cardiac TnI was assayed on Access AccuTnI (Beckman Coulter) with the minimal detectable concentration reported by the manufacturer of 0.01 ng/mL, a 99th percentile upper reference limit of 0.04 ng/mL, and a recommended cutoff for AMI of 0.1 ng/mL. Values above 100 ng/mL were labeled ">100" without further attempts to define the exact values. The coefficient of variation of the assay is reported to be 20% at 0.03 ng/mL, 14% at 0.04 ng/mL, and 10% at 0.06 ng/mL. Also according to the manufacturer, the antibodies selected for the Access AccuTnI assay bind to epitopes located in the stable region of the molecule (amino acids [aa] 30 to 110)14 and has been proposed to measure both complexed and intact free cTnI but may or may not bind degradation products.
Electrophoresis and Western BlotDirect Serum Assay
Detection of serum cTnI by Western blotdirect serum assay (WB-DSA) was performed under denaturing and reducing conditions. Serum was diluted 20-fold in sample buffer containing 16.5 mg/mL sodium dodecyl sulfate, 16.5 mg/mL 3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulfonate (CHAPS), 1.65% Nonidet P-40, 0.5 mol/L dithiothreitol, 1 mol/L urea, 0.25 mol/L Tris-HCl (pH 6.8), 0.01% wt/vol bromophenol blue, and 50% mL of glycerol. One microliter of neat serum was resolved by 12% SDS-PAGE (40% acrylamide/bis solution, 37.5:1 [C 2.6%]; Mini Protean II, Bio-Rad) in electrode buffer containing 0.025 mol/L Tris Base, 0.25 mol/L glycine, and 0.1% SDS, at 65 V for 15 minutes, then 135 V for 110 minutes at 4°C. Gel-resolved proteins were then transferred onto a polyvinylidene difluoride membrane (0.2 µm; Bio-Rad) in the presence of 10 mmol/L CHAPS (pH 11), for 1 hour at 100 V, at 4°C using a Mini Trans-Blot Cell apparatus (Bio-Rad). Membranes were blocked for 1 hour at room temperature in 10% blocking reagent (Roche Diagnostics) diluted with 1x PBS with Tween 20, and probed at 4°C overnight with monoclonal anti-cTnI antibody 8-I7 (epitope aa 137 to 148; Spectral Diagnostics), 3-E3 (aa 55 to 94; Spectral Diagnostics; both epitopes are located at the stable fragment of cTnI), as well as G-131-C (aa 1 to 15; BiosPacific). All primary antibodies were diluted in 1% blocking reagent (0.5 µg of primary antibody per milliliter of blocking reagent). Primary antibodies were detected using alkaline phosphatase (AP)-conjugated goat anti-mouse IgG (anti-cTnI antibody 8-I7 and 3-E3) or AP-conjugated rabbit anti-goat IgG (anti-cTnI antibody G-131-C) (both from The Jackson Laboratory). All secondary antibodies were diluted in 1% blocking reagent (1:3000 dilution) and membranes were incubated for 1 hour at room temperature. Signals were visualized using Immun-Star AP chemiluminescent kit (Bio-Rad) and film (X-Omat Blue XB-1, 18x24 cm, Kodak) and were within the linear range. Sera were analyzed 2 times, and the corresponding results were consistent.
Purification Methods
IDM (Interaction Discovery Mapping) Affinity Beads (Ciphergen Biosystems Inc, Fremont, Calif) were used for pull-down purification and enrichment of cTnI. The protocol of coupling an antibody to IDM Affinity Beads and subsequent capture and elution of antigen, as described by the manufacturer, was used. The beads (10 µL) were washed with water and added 200 µL of coupling buffer (50 mmol/L sodium bicarbonate, pH 9.2) and 5 µL of 8-I7 antibody. After incubation overnight at 4°C, the beads were washed with coupling buffer and then by a Tris/Triton X buffer (0.5 mol/L Tris HCl, pH 9.0, 0.1% Triton X-100). To reduce unspecific reactions, the beads were blocked with 1 mg/mL BSA in Tris/Triton X buffer for 1 hour at room temperature. After blocking, the beads were washed with PBS, added to 50 µL of serum and 150 µL of PBS, and incubated for 1 hour at room temperature. The beads were subsequently washed 4 times in 1 mol/L urea, 50 mmol/L Tris HCl (pH 7.2), 0.1 mol/L NaCl, 0.1% CHAPS, and finally in PBS and water before they were added 20 µL of SDS-PAGE sample buffer, to elute bound protein from the beads.
Image Quantification
The ImageQuant TL Software (Amersham Biosciences) was used to visualize the release pattern and to estimate the size of the individual degradation products. As a standard, we used purified human cTnI from HyTest Ltd (Turku, Finland) with a molecular mass of 23.876 kDa reported by the manufacturer, which allowed for an internal consistency check regarding the localization of cTnI after gel migration during electrophoresis. To express the release pattern semiquantitatively, we adjusted the intensity of the signal from each band to the signal of the intact purified human cTnI, which was loaded in equal concentrations on each immunoblot.
Statistical Analysis
All data with a normal distribution are presented as mean±SD with range in parentheses. Differences between groups were examined with Students t tests. A value of P<0.05 was considered statistically significant. All statistical analyses were performed using SPSS 11.5 software.
| Results |
|---|
|
|
|---|
At baseline, ie, immediately before initiation of thrombolytic treatment, 23 of 26 patients (88%) had cTnI levels above the minimal detectable limit with thirteen patients (50%) above the diagnostic cutoff for AMI (
0.1 ng/mL). Although there can be a higher rate of false-positive results near the lower detection limit, cTnI could be detected by WB-DSA in all patients at baseline. Time from onset of symptoms to initiation of treatment was 206±68 minutes (mean±SD; range, 105 to 420 minutes) with time from baseline to initiation of treatment 9±5 minutes (mean±SD; range, 3 to 20 minutes). Increasing levels of cTnI occurred over the course of the sampling and all patients eventually exceeded the cTnI cutoff for AMI.
The anti-cTnI antibody 3-E3 detected in all patients a minimum of 2 bands on immunoblot, namely intact cTnI and a single degradation product (molecular mass, 23.5 and 20 kDa, respectively) as early as in their baseline samples (from 90 minutes after onset of symptoms). Eleven patients showed only increases in the intensity of the signals from the 2 fragments, but no further degradation. Of these patients, 5 reached maximum CK and CK-MB levels of 2 to 5 times the upper reference limit (URL); the remaining >5 times the URL. Progressive degradation, on the other hand, was found in 15 of the 26 patients, all of which reached maximum CK and CK-MB levels >5 times the URL. Immunoblot showed multiple degradation products with a molecular mass less than intact cTnI with up to 7 degradation bands, all molecular mass >12 kDa, appearing at a mean of 261±64 minutes after onset of chest pain (range 165 to 355 minutes). In these patients, time from initiation of treatment to the appearance of more than 1 degradation product was 68±53 minutes (0 to 145 minutes). The appearance of more than 1 detectable degradation fragment was dependent on the cTnI level. Only 1 degradation band appeared at low concentrations, followed by an increasing number of degradation products with increasing measured concentrations (P<0.001).
The finding of intact cTnI and up to 7 smaller fragments in some patient samples was consistent for both primary antibodies, but anti-cTnI antibody 3-E3 was able to demonstrate all bands, whereas anti-cTnI antibody 8-I7 was unable to detect the presence of the 2 smallest fragments. Also, unlike anti-cTnI antibody 3-E3, the anti-cTnI antibody 8-I7 was only able to visualize intact cTnI, but not the initial degradation fragment in the baseline sample of 6 patients, which was independent of measured concentrations of cTnI. The third primary antibody, G-131-C, was used only to confirm the bands as being products of troponin degradation when verification was needed (data not shown). All samples were tested with secondary antibody alone and showed no cross-reactivity.
Figure 1 depicts representative blots showing progressive cTnI degradation from time 0 through 180 minutes in 2 patients with ultimately high concentrations of cTnI using 2 different primary anti-cTnI antibodies. In contrast to these findings, Figure 2 shows representative blots of cTnI degradation from time 0 through 180 minutes in 2 patients with relatively low concentrations of cTnI using the same antibodies. In both blots, human purified intact cTnI was used as a positive control. Timing began immediately before initiation of thrombolytic treatment (t=0), and subsequent time intervals are listed for each Western blot.
|
|
The concentration of cTnI in serum is at least 100 000 times less than that of the most abundant serum proteins. Results from Western blotting with anti-cTnI antibodies using crude serum should therefore be interpreted with care because of the possibility of unspecific binding to more abundant proteins. To verify the cTnI identity of the Western blot bands, we performed pull-down procedures, ie, immunoprecipitation with an anti-cTnI antibody. This procedure could not be expected to give pure cTnI, but a strong reduction of contaminating proteins, and hence an enrichment of cTnI could be possibly expected. The pull-down products were subsequently analyzed by SDS-PAGE and Western blotting. We found that bands corresponding to bands from crude serum presumably marking intact cTnI and degradation products indeed were enriched, whereas dense bands from crude serum (probably corresponding to albumin and immunoglobulin) were strongly reduced after the pull-down procedure (Figure 3). This reduces the risk of our results being false positives.
|
The release and clearance pattern for intact cTnI (band 1) and the primary degradation band (band 2) are shown in Figure 4, including SDs. The remaining degradation products are not shown in this format, but Figure 5 summarizes the release pattern for bands 1 to 8. The figure shows bands 1 and 2 being present at an earlier stage than the remaining bands following the same release pattern, with a less steep increase in concentration at the end of the sampling period. The other degradation fragments show a more rapid increase in concentration as measured by their corrected intensity.
|
|
The molecular mass estimate based on mobility in the SDS-PAGE gel for intact cTnI and the smaller degradation product confirmed that there was consistency in the appearance of the different fragments when using blots with both anti-cTnI antibody 3-E3 and 8-I7, except for the difference in sensitivity to show the presence of the 2 bands. For intact cTnI, we found an approximate molecular mass of 23.5 kDa (band 1), with subsequently decreasing size of the following degradation fragments of 20.0 (band 2), 18.5 (band 3), 17.0 (band 4), 16.5 (band 5), 15.5 (band 6), 14.0 (band 7), and 12.0 kDa (band 8) (data from immunoblots visualized by anti-cTnI antibody 3-E3). The particular products "intact cTnI" and "band 2" corresponding to molecular mass 23.5 and 20.0 kDa were present at baseline in all patients as previously described, whereas bands 3 and 5 were the most abundant of the subsequent degradation products. In patients who demonstrated several degradation products, there was a trend toward earlier initiation of treatment after onset of symptoms (184±41 minutes) as compared with patients with only 2 bands on immunoblot (235±87 minutes; P=0.058). We could not detect any significant relation between infarct location and fragment patterns, just as we did not find any relationship between the relative increase in intensity of bands and time from onset of symptoms to initiation of treatment in patients who demonstrated several degradation products as a possible indicator of differences in degree of reperfusion.
| Discussion |
|---|
|
|
|---|
Previous studies have shown a correlation between concentrations of cTnT and cTnI and infarct size, suggesting levels 72 hours after AMI the most specific for evaluating infarct size using commercial tests that may or may not detect the degradation products.15,16 Ohlmann et al15 were able to demonstrate a significant correlation between infarct size and cTnI levels as early as 3 hours after primary percutaneous coronary intervention. In our study, infarct size, as estimated by the concentration of cTnI also 3 hours after thrombolysis, was the major determinant for the presence of several degradation products. Up to 7 degradation fragments from both the N and C termini were seen in addition to intact cTnI, and these results are in agreement with previous studies conducted by Labugger et al.17 The fact that antibody 8-I7 is not able to detect the 2 smallest fragments suggests that the cleavage is within its epitope (aa 137 to 148) and therefore splits the molecule essentially in half.
As suggested by earlier studies, the pattern of release of the different cTnI forms after AMI may vary over time, with intact ternary complexes predominantly early, followed by binary complexes, free forms, and immunoreactive fragments mostly later in the course.1821 In our study, we were not able to visualize complexes of cTnI. Intact cTnI was the primary product detected and it was detected early after the onset of symptoms. Subsequently, we observed degradation products with a smaller molecular mass. This may represent the fact that early release comes from the free form of cTnI present in the cytosol but does not exclude the presence of larger complexes being the primary form in the blood after a myocardial infarction. Also we do not know whether thrombolysis or preparation of blood samples for immunoblotting is of importance in degradation of cTn.
As Figures 4 and 5
show, the increase in concentration diminishes after the initial release with the smaller fragments dominating the picture in peripheral blood by the end of the sampling period. This is suggestive of differences in clearance and release kinetics of the various cTnI products. The concentration of cTnI, measured by a commercially available assay, increases rapidly during the sampling period and must therefore almost solely represent detection of larger complexes or smaller degradation products band 3 to 8. Whether the individual fragments seen on our immunoblots originate from intact cTnI with degradation from the N- and C-terminal part of the molecule per se or represents products from disintegration of complexes remains to be elucidated.
The release pattern of troponin may be dependent on the time from onset of the coronary occlusion to recanalization, if achieved, and the abruptness of the reperfusion. In addition comparisons are problematic because of a different amount of troponin being released into the blood depending on the degree of revascularization. Our data show that patients with only 2 bands on immunoblot had low concentrations of cTnI in the very early phase of AMI (ie, the sampling period; 0 to 300 minutes) and generally lower values and/or later peak concentrations of CK/CK-MB during hospitalization. Combining these facts with the concept suggested previously that most of the troponin is degraded in the myocardium and not in peripheral blood,17 one could speculate whether the patients with the relatively early release of multiple degradation products represent the patients who benefited the most from thrombolytic treatment, whereas the remaining patients have not been sufficiently reperfused and will show a relatively larger, but slower increase in cTnI concentration at a later time point. Some patients, however, have low levels of CK-MB, but peak at the same time as patients with high levels, and could simply represent a cohort with smaller infarctions. The range of cTnI concentration in which there is no further degradation beyond intact cTnI and band 2 is 0.02 to 30.50 ng/mL. We see further degradation in a range of 0.07 to >100 ng/mL. This does not exclude, but diminishes, the possibility of not visualizing degradation products because the severity of the injury is not enough to release cTnI in a concentration sufficient to visualize degradation products on the gels.
Strength and Limitations
The study is a single-center study with a randomized design within the framework of a major STEMI trial and with uniform time frequency of blood drawing. Limitations were the small number of patients and the lack of further clinical information, including follow-up. Unfortunately, we also do not have any information regarding the degree of achieved reperfusion by the administered fibrinolytic therapy, just as we do not know the time course of cTnI concentrations past the initial 180 minutes after treatment initiation (ie, our sampling period).
| Conclusion |
|---|
|
|
|---|
| Acknowledgments |
|---|
Sources of Funding
This study was supported by The Medical Research Foundation, Region of Greater Copenhagen, the Faroe Islands and Greenland; the Danish Heart Foundation; the National Association of Norway for Public Health, the Norwegian Council for Heart and Vessels; the Eastern Regional Health Authority of Norway; and the Aker University Hospital Research Foundation.
Disclosures
None.
| Footnotes |
|---|
Original received May 27, 2006; revision received September 19, 2006; accepted September 29, 2006.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
M. P. Bonaca and D. A. Morrow Defining a Role for Novel Biomarkers in Acute Coronary Syndromes Clin. Chem., September 1, 2008; 54(9): 1424 - 1431. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Circulation Research Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2006 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |