Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation Research
Search: search_blue_button Advanced Search
Circulation Research. 1999;84:378-383

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rogers, C.
Right arrow Articles by Edelman, E. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rogers, C.
Right arrow Articles by Edelman, E. R.
Related Collections
Right arrow Restenosis
Right arrow Catheter-based coronary interventions: stents
Right arrow Other Vascular biology
(Circulation Research. 1999;84:378-383.)
© 1999 American Heart Association, Inc.


Original Contribution

Balloon-Artery Interactions During Stent Placement

A Finite Element Analysis Approach to Pressure, Compliance, and Stent Design as Contributors to Vascular Injury

Presented at the 23rd Annual Meeting of the Society for Biomaterials, New Orleans, La, April 30–May 4, 1997, and the 70th Scientific Sessions of the American Heart Association, Orlando, Fla, November 9–12, 1997, and published in abstract form (Circulation. 1997;96[suppl I]:I-402).

Campbell Rogers, David Y. Tseng, James C. Squire, Elazer R. Edelman

From the Cardiac Catheterization Laboratory and Coronary Care Unit, Cardiovascular Division, Brigham and Women's Hospital, Harvard Medical School, Boston, Mass, and Harvard-MIT Division of Health Science and Technology, Massachusetts Institute of Technology, Cambridge, Mass.

Correspondence to Campbell Rogers, MD, Cardiovascular Division, Brigham and Women's Hospital, 75 Francis St, Boston, MA 02115. E-mail cdrogers{at}bics.bwh.harvard.edu

Abstract—Endovascular stents expand the arterial lumen more than balloon angioplasty and reduce rates of restenosis after coronary angioplasty in selected patients. Understanding the factors involved in vascular injury imposed during stent deployment may allow optimization of stent design and stent-placement protocols so as to limit vascular injury and perhaps reduce restenosis. Addressing the hypothesis that a previously undescribed mechanism of vascular injury during stent deployment is balloon-artery interaction, we have used finite element analysis to model how balloon-artery contact stress and area depend on stent-strut geometry, balloon compliance, and inflation pressure. We also examined superficial injury during deployment of stents of varied design in vivo and in a phantom model ex vivo to show that balloon-induced damage can be modulated by altering stent design. Our results show that higher inflation pressures, wider stent-strut openings, and more compliant balloon materials cause markedly larger surface-contact areas and contact stresses between stent struts. Appreciating that the contact stress and contact area are functions of placement pressure, stent geometry, and balloon compliance may help direct development of novel stent designs and stent-deployment protocols so as to minimize vascular injury during stenting and perhaps to optimize long-term outcomes.


Key Words: stent • restenosis • vascular injury • balloon • finite element analysis




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
G. A. Holzapfel, G. Sommer, C. T. Gasser, and P. Regitnig
Determination of layer-specific mechanical properties of human coronary arteries with nonatherosclerotic intimal thickening and related constitutive modeling
Am J Physiol Heart Circ Physiol, November 1, 2005; 289(5): H2048 - H2058.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
B. Balakrishnan, A. R. Tzafriri, P. Seifert, A. Groothuis, C. Rogers, and E. R. Edelman
Strut Position, Blood Flow, and Drug Deposition: Implications for Single and Overlapping Drug-Eluting Stents
Circulation, June 7, 2005; 111(22): 2958 - 2965.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
F. Vogt, A. Stein, G. Rettemeier, N. Krott, R. Hoffmann, J. v. Dahl, A.-K. Bosserhoff, W. Michaeli, P. Hanrath, C. Weber, et al.
Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent
Eur. Heart J., August 1, 2004; 25(15): 1330 - 1340.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. F. LaDisa Jr., L. E. Olson, I. Guler, D. A. Hettrick, S. H. Audi, J. R. Kersten, D. C. Warltier, and P. S. Pagel
Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery
J Appl Physiol, July 1, 2004; 97(1): 424 - 430.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J Gunn, N Arnold, K H Chan, L Shepherd, D C Cumberland, and D C Crossman
Coronary artery stretch versus deep injury in the development of in-stent neointima
Heart, October 1, 2002; 88(4): 401 - 405.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. Briguori, C. Sarais, P. Pagnotta, F. Liistro, M. Montorfano, A. Chieffo, F. Sgura, N. Corvaja, R. Albiero, G. Stankovic, et al.
In-stent restenosis in small coronary arteries: Impact of strut thickness
J. Am. Coll. Cardiol., August 7, 2002; 40(3): 403 - 409.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
M. Haude and R. Erbel
How big is small?
Eur. Heart J., February 1, 2002; 23(3): 198 - 199.
[Full Text] [PDF]


Home page
Eur Heart JHome page
C. Briguori, J. Tobis, T. Nishida, M. Vaghetti, R. Albiero, C. Di Mario, and A. Colombo
Discrepancy between angiography and intravascular ultrasound when analysing small coronary arteries
Eur. Heart J., February 1, 2002; 23(3): 247 - 254.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S. Windecker and B. Meier
All stents are not alike or is the difference in the eye of the observer only?
Eur. Heart J., November 1, 2001; 22(21): 1973 - 1977.
[PDF]


Home page
Eur Heart JHome page
R. Hoffmann, C. Jansen, A. Konig, P.K. Haager, G. Kerckhoff, J. Vom Dahl, V. Klauss, P. Hanrath, and H. Mudra
Stent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study
Eur. Heart J., November 1, 2001; 22(21): 2007 - 2014.
[Abstract] [PDF]


Home page
CirculationHome page
S. Windecker, I. Mayer, G. De Pasquale, W. Maier, O. Dirsch, P. De Groot, Y.-P. Wu, G. Noll, B. Leskosek, B. Meier, et al.
Stent Coating With Titanium-Nitride-Oxide for Reduction of Neointimal Hyperplasia
Circulation, August 21, 2001; 104(8): 928 - 933.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Vernhet, R. Demaria, J. M. Juan, M. C. Oliva-Lauraire, J. P. Senac, and M. Dauzat
Changes in Wall Mechanics After Endovascular Stenting in the Rabbit Aorta: Comparison of Three Stent Designs
Am. J. Roentgenol., March 1, 2001; 176(3): 803 - 807.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. E. Drachman, E. R. Edelman, P. Seifert, A. R. Groothuis, D. A. Bornstein, K. R. Kamath, M. Palasis, D. Yang, S. H. Nott, and C. Rogers
Neointimal thickening after stent delivery of paclitaxel: change in composition and arrest of growth over six months
J. Am. Coll. Cardiol., December 1, 2000; 36(7): 2325 - 2332.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
R. Hoffmann and G.S. Mintz
Coronary in-stent restenosis--predictors, treatment and prevention
Eur. Heart J., November 1, 2000; 21(21): 1739 - 1749.
[PDF]


Home page
CirculationHome page
J. M. Ahmed, G. S. Mintz, N. J. Weissman, A. J. Lansky, A. D. Pichard, L. F. Satler, and K. M. Kent
Mechanism of Lumen Enlargement During Intracoronary Stent Implantation : An Intravascular Ultrasound Study
Circulation, July 4, 2000; 102(1): 7 - 10.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. M. Garasic, E. R. Edelman, J. C. Squire, P. Seifert, M. S. Williams, and C. Rogers
Stent and Artery Geometry Determine Intimal Thickening Independent of Arterial Injury
Circulation, February 22, 2000; 101(7): 812 - 818.
[Abstract] [Full Text] [PDF]


Home page
Circ. Res.Home page
M. Overhaus, J. Heckenkamp, S. Kossodo, D. Leszczynski, and G. M. LaMuraglia
Photodynamic Therapy Generates a Matrix Barrier to Invasive Vascular Cell Migration
Circ. Res., February 18, 2000; 86(3): 334 - 340.
[Abstract] [Full Text] [PDF]