Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation Research
Search: search_blue_button Advanced Search
Circulation Research. 1991;68:1751-1760

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Abboud, S.
Right arrow Articles by Sadeh, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Abboud, S.
Right arrow Articles by Sadeh, D.

Circulation Research, Vol 68, 1751-1760, Copyright © 1991 by American Heart Association


ARTICLES

Simulation of high-resolution QRS complex using a ventricular model with a fractal conduction system. Effects of ischemia on high-frequency QRS potentials

S Abboud, O Berenfeld and D Sadeh
Biomedical Engineering Program, Faculty of Engineering, Tel Aviv University, Israel.

Recent studies have analyzed the high-fidelity surface electrocardiographic signal, and efforts have been made to increase the diagnostic sensitivity of the electrocardiogram by observing its high- frequency components. It was found that the high-frequency (150-250-Hz) electrocardiogram appears to detect evidence of transient ischemia with greater sensitivity than visual inspection of the surface electrocardiogram. A finite-element three-dimensional model of the ventricles with a self-similar (fractal) conduction system has been introduced as a bridge to the understanding of electrocardiographic phenomena related to high-frequency potentials. The model was activated, and the dipole potential generated by adjacent activated and resting cells was calculated to obtain a high-resolution QRS complex. Normal and ischemic activation processes was stimulated by regional reduction in conduction velocity. It was found that although the resulted low-frequency QRS complex was not significantly altered from normal conditions, the high-frequency components exhibited morphological changes similar to the ones observed during animal experiments and human studies. Based on the results obtained from the model, it can be concluded that these morphological changes can be attributed to a slowing of conduction velocity in the region of ischemia and that the model is adequate for meeting the challenges imposed by the requirements of high-frequency methods applied in clinical cardiology.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
S. Matsushita, Y. Sakakibara, T. Imazuru, M. Noma, Y. Hiramatsu, O. Shigeta, T. Jikuya, and T. Mitsui
High-frequency QRS potentials as a marker of myocardial dysfunction after cardiac surgery
Ann. Thorac. Surg., April 1, 2004; 77(4): 1293 - 1297.
[Abstract] [Full Text] [PDF]


Home page
Mayo Clin Proc.Home page
T. T. Schlegel, W. B. Kulecz, J. L. Depalma, A. H. Feiveson, J. S. Wilson, M. A. Rahman, and M. W. Bungo
Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease
Mayo Clin. Proc., March 1, 2004; 79(3): 339 - 350.
[Abstract] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
A. L. Goldberger, L. A. N. Amaral, J. M. Hausdorff, P. Ch. Ivanov, C.-K. Peng, and H. E. Stanley
Fractal dynamics in physiology: Alterations with disease and aging
PNAS, February 19, 2002; 99(suppl_1): 2466 - 2472.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. Pettersson, O. Pahlm, E. Carro, L. Edenbrandt, M. Ringborn, L. Sornmo, S. G. Warren, and G. S. Wagner
Changes in high-frequency QRS components are more sensitive than ST-segment deviation for detecting acute coronary artery occlusion
J. Am. Coll. Cardiol., November 15, 2000; 36(6): 1827 - 1834.
[Abstract] [Full Text] [PDF]


Home page
Circ. Res.Home page
O. Berenfeld and J. Jalife
Purkinje-Muscle Reentry as a Mechanism of Polymorphic Ventricular Arrhythmias in a 3-Dimensional Model of the Ventricles
Circ. Res., June 1, 1998; 82(10): 1063 - 1077.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
L. A. Lipsitz and A. L. Goldberger
Loss of 'Complexity' and Aging: Potential Applications of Fractals and Chaos Theory to Senescence
JAMA, April 1, 1992; 267(13): 1806 - 1809.
[Abstract] [PDF]