Circulation Research, Vol 55, 238-248, Copyright © 1984 by American Heart Association
ARTICLES |
PN Uhlig, RW Baer, GJ Vlahakes, FL Hanley, LM Messina and JI Hoffman
The coronary circulation of anesthetized dogs was tested for the presence of vascular waterfalls by manipulating coronary arterial and coronary venous pressures. The left main coronary artery and the coronary sinus were cannulated, and relationships between coronary artery pressure, coronary sinus pressure, and coronary flow were studied. Experiments were conducted during diastolic arrests, under steady state conditions, in the absence of autoregulation. Relations of coronary flow to coronary sinus pressure at constant coronary artery pressure were consistent with the presence of a vascular waterfall in the coronary sinus. When the great cardiac vein was cannulated, relations of great vein flow to great vein pressure at constant coronary artery pressure were consistent with the presence of a vascular waterfall in the great vein, indicating that waterfall behavior can occur in epicardial veins other than the coronary sinus. In dogs on right heart bypass, with the coronary sinus and great vein uncannulated, the relationship between right atrial pressure and coronary sinus pressure showed a waterfall pattern, indicating that the waterfall is not an artifact of venous cannulation. In the right heart bypass experiments, venous waterfall behavior was seen in beating hearts as well as during diastolic arrests. We conclude that a vascular waterfall is present in epicardial coronary veins which can significantly influence coronary blood flow.
This article has been cited by other articles:
![]() |
D. J. Duncker and R. J. Bache Regulation of Coronary Blood Flow During Exercise Physiol Rev, July 1, 2008; 88(3): 1009 - 1086. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Westerhof, C. Boer, R. R. Lamberts, and P. Sipkema Cross-talk between cardiac muscle and coronary vasculature. Physiol Rev, October 1, 2006; 86(4): 1263 - 1308. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. P. Versluis, J. W. Heslinga, P. Sipkema, and N. Westerhof Microvascular pressure measurement reveals a coronary vascular waterfall in arterioles larger than 110 {micro}m Am J Physiol Heart Circ Physiol, November 1, 2001; 281(5): H1913 - H1918. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. S. Aldea, H. Mori, W. K. Husseini, R. E. Austin, and J. I. E. Hoffman Effects of increased pressure inside or outside ventricles on total and regional myocardial blood flow Am J Physiol Heart Circ Physiol, December 1, 2000; 279(6): H2927 - H2938. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Nanto, T. Masuyama, M. Hori, T. Shimonagata, T. Ohara, and S. Kubori Zero Flow Pressure in Human Coronary Circulation Angiology, February 1, 1996; 47(2): 115 - 122. [Abstract] [PDF] |
||||
|
Circulation Research Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1984 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |