Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation Research
Search: search_blue_button Advanced Search
Circulation Research. 1983;53:264-273

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Savard, P.
Right arrow Articles by Madias, J. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Savard, P.
Right arrow Articles by Madias, J. E.

Circulation Research, Vol 53, 264-273, Copyright © 1983 by American Heart Association


ARTICLES

Magnetic measurement of S-T and T-Q segment shifts in humans. Part I: Early repolarization and left bundle branch block

P Savard, D Cohen, E Lepeschkin, BN Cuffin and JE Madias

The direct-current magnetocardiogram not only shows the features usually seen on the electrocardiogram, but also shows the T-Q (baseline) shift due to cardiac injury current. The first direct- current magnetocardiogram measurements of the human heart are presented here. The hypothesis tested is that there is no injury current associated with the S-T shift seen in two electrocardiogram abnormalities: early repolarization, and left bundle branch block. The data from three typical early repolarization subjects and one typical left bundle branch block patient are presented. It is found, in each case, that although there is appreciable S-T shift, there is essentially no baseline shift on the direct-current magnetocardiogram. The absence of baseline shift proves that the S-T shifts in these cases are not "apparent" shifts, caused by a dc injury current which is interrupted during the S-T interval; instead, these are "true" S-T shifts caused by a current flowing only during systole, presumably due to an altered repolarization of the ventricles. It is also found that the direct-current magnetocardiogram does not have routine clinical application because of a practical problem. This is the presence of false baseline shifts due to noncardiac currents, mostly in the gastrointestinal tract, which could be suppressed in only about one- third of the subjects. However, the direct-current magnetocardiogram may be useful as a research tool, for clarifying the cause of the S-T shift in selected subjects.