Circulation Research, Vol 38, 347-356, Copyright © 1976 by American Heart Association
ARTICLES |
CF Rothe and JA Drees
The mean circulatory pressure (Pmc) in dogs anesthetized with chloralose-urethane was estimated from 0.5 to 150 minutes after hemorrhages of 0, 17, or 34 ml/kg, or that volume giving an arterial pressure (Pa) of 40 mm Hg. The Pmc was determined by fibrillating the heart and then rapidly pumping blood from aorta to vena cava until Pa=venous pressure (Pv)=Pmc. Within about 10 seconds, the heart was defibrillated. Vascular compliance was estimated as the ratio of a test blood volume change (0, +/- 8.5, or 17 ml/kg) to the change in Pmc, determined 0.5 minute after the start of the test volume change. Erythrocyte and plasma volumes were measured by 51Cr-erythrocyte and 125I-albumin dilution. In response to prolonged hemorrhage: (1) the total vascular compliance apparently decreased; (2) most of the changes in capacity vessels occurred within 5 minutes, and indeed a large part of the response probably had occurred by the time of the first measurement at 30 seconds; (3) the progressive recovery in Pmc after 5 minutes was primarily from fluid shifting into the vasculature; (4) even after 2 hours of severe hemorrhagic hypotension, the venoconstriction was not lost; but (5) after an hour of severe hemorrhagic hypotension (arterial pressure of 40 mm Hg) there was water loss from the vasculature, because plasma protein and erythrocyte concentrations and plasma oncotic pressure increased.
This article has been cited by other articles:
![]() |
M. Skals, N. Skovgaard, A. S. Abe, and T. Wang Venous tone and cardiac function in the South American rattlesnake Crotalus durissus: mean circulatory filling pressure during adrenergic stimulation in anaesthetised and fully recovered animals J. Exp. Biol., October 1, 2005; 208(19): 3747 - 3759. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Syuu, H. Matsubara, S. Hosogi, and H. Suga Pressor effect of electroacupuncture on hemorrhagic hypotension Am J Physiol Regulatory Integrative Comp Physiol, December 1, 2003; 285(6): R1446 - R1452. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-J. Wang, A. B. O'Brien, N. G. Shrive, K. H. Parker, and J. V. Tyberg Time-domain representation of ventricular-arterial coupling as a windkessel and wave system Am J Physiol Heart Circ Physiol, April 1, 2003; 284(4): H1358 - H1368. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. K. Peters, G. Lister, E. R. Nadel, and G. W. Mack Venous and arterial reflex responses to positive-pressure breathing and lower body negative pressure J Appl Physiol, June 1, 1997; 82(6): 1889 - 1896. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. F. Rothe Physiology of Venous Return: An Unappreciated Boost to the Heart Arch Intern Med, May 1, 1986; 146(5): 977 - 982. [Abstract] [PDF] |
||||
|
Circulation Research Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 1976 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |