Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation Research
Search: search_blue_button Advanced Search
Circulation Research. 1974;35:826-834

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by MASERI, A.
Right arrow Articles by D'ANGELO, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by MASERI, A.
Right arrow Articles by D'ANGELO, T.
(Circulation Research. 1974;35:826.)
© 1974 American Heart Association, Inc.


Contribution of Recirculation and Fat Diffusion to Myocardial Washout Curves Obtained by External Counting in Man

Stochastic Versus Monoexponential Analysis

ATTILIO MASERI 1, ANTONIO PESOLA 1, ANTONIO L'ABBATE 1, CARLO CONTINI 1, CLAUDIO MICHELASSI 1, TOMMASO D'ANGELO 1

1 Laboratorio di Fisiologia Clinica del Consiglio Nazionale delle Ricerche Via Savi 8, Pisa, Italy

133Xenon and 125I-iodoantipyrine (IAP) solutions were simultaneously injected into the left coronary artery in four normal patients and four patients with coronary artery obstructions. Recirculation was computed by convolution of the fractional decrease of the curve following inlet injection over a second curve obtained following right atrial injection. Uncorrected xenon and IAP curves were not statistically different in spite of the lower myocardium-blood partition coefficient and the recirculation of xenon. Corrected IAP curves could be followed down to 1.7%, whereas xenon curves could be followed only to 7.5%, indicating significant xenon diffusion holdup in fat. Corrected IAP curves deviated from a monoexponential course below 5% of peak in normal patients and at about 10% in patients with coronary artery obstructions. Stochastic analysis gave flow values 22% lower and 45% higher, respectively, than those computed from monoexponential extrapolation of corrected IAP and uncorrected xenon curves. With the double-injection technique, IAP washout can be calculated down to about 1% of peak, accounting for the distribution of 99% of the flow through the tissue to which the indicator is delivered. Monoexponential analysis of corrected IAP curves overestimates flow, because it cannot fit the initial delay component and the final reduction of slope. Xenon washout does not allow quantification of myocardial flow in man.


Key Words: diffusible indicator • 125I-iodoantipyrine • 133xenon convolution • nonhomogeneous perfusion • coronary obstruction

Submitted on October 29, 1973
Accepted on August 11, 1974