Circulation Research. 1970;27:995-1001

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by REUBEN, S. R.
Right arrow Articles by LEE, G. D. J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by REUBEN, S. R.
Right arrow Articles by LEE, G. D. J.
(Circulation Research. 1970;27:995.)
© 1970 American Heart Association, Inc.


Velocity Profiles in the Main Pulmonary Artery of Dogs and Man, Measured with a Thin-Film Resistance Anemometer

S. R. REUBEN M.B.1, J. P. SWADLING 1, G. DE J. LEE M.A., M.D.1

1 Cardiac Department and Nuffield Department of Medicine, Radcliffe Infirmary Oxford, England

Instantaneous velocity of pulmonary artery blood was measured using a thin-film resistance anemometer mounted on a hypodermic needle. Studies were performed, at thoracotomy, in five dogs and five patients. Instantaneous blood velocity was recorded at several sites across the transverse axis of the main pulmonary artery to determine the shape of the velocity profile.

We found the velocity profile, in both man and dog, to be approximately flat. In dog, the mean velocity, normalized to that at the center line, ranged from 1.18 (SD ± 0.03) to 0.81 (SD ± 0.27). In man, mean velocity of pulmonary artery blood, normalized in a similar fashion, ranged from 1.08 (SD ± 0.03) to 0.84 (SD ±0.07), while the normalized peak systolic velocity ranged from 1.04 (SD ± 0.07) to 0.95 (SD ± 0.16). The results, in dogs, suggest that there is little asymmetry of the velocity profile and therefore these have been taken as evidence that the use of cuff electromagnetic flowmeters on the pulmonary artery of dogs is not subject to significant inaccuracies associated with a nonsymmetrical flow profile. The finding of a relatively flat velocity profile in patients, moreover, will make it easier for catheter-tip flowmeters to measure bulk velocity in the pulmonary artery.


Key Words: axi-symmetrical • Fourier analysis • electromagnetic • impedance • pulmonary hypertension

Submitted on May 27, 1970
Accepted on October 3, 1970




This article has been cited by other articles:


Home page
CirculationHome page
H. Senzaki, S. Masutani, J. Kobayashi, T. Kobayashi, N. Sasaki, H. Asano, S. Kyo, Y. Yokote, and A. Ishizawa
Ventricular Afterload and Ventricular Work in Fontan Circulation: Comparison With Normal Two-Ventricle Circulation and Single-Ventricle Circulation With Blalock-Taussig Shunts
Circulation, June 18, 2002; 105(24): 2885 - 2892.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
E. Sloth, K. C. Houlind, E. M. Pedersen, and J.M. Hasenkam
Where to place the Doppler sample volume in the human main pulmonary artery: evaluated from magnetic resonance phase velocity maps
Cardiovasc Res, January 1, 1997; 33(1): 156 - 163.
[Abstract] [Full Text] [PDF]