Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation Research
Search: search_blue_button Advanced Search
Circulation Research. 1970;27:1033-1045

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by MESEL, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by MESEL, E.
(Circulation Research. 1970;27:1033.)
© 1970 American Heart Association, Inc.


Direct Measurement of Intracardiac Blood Flow in Dogs with Experimental Ventricular Septal Defects

EMMANUEL MESEL M.D.1

1 Department of Pediatrics, Stanford University School of Medicine Palo Alto, California 94305

Experimental ventricular septal defects (VSD's) were produced in dogs under general anesthesia by excising a 9-mm core of tissue from the septum with a cylindrical cutting tool. A specially designed electromagnetic flow transducer was wedged into the defect compressing the septal tissue around it, thus causing all of the shunted blood to pass through the lumen. The sensing electrodes were in direct contact with the blood stream, allowing the transducer to be calibrated externally, and to be used as a primary standard of measurement. When left-to-right shunts were measured by the Fick technique, the average error was 57percnt; (2% to 154%). When pulmonary arterial oxygen saturation exceeded 85%, measurements using the Fick method showed errors greater than 30% (61% to 154%) in 9 of 11 animals. The VSD's were of moderate size and resulted in right ventricular systolic pressures between 1/4; and 1/2; of systemic. The flow pattern and the interventricular pressure difference were remarkably similar in contour. Delay in right ventricular activation occurred in most animals as a result of surgical disturbance of the conduction system. Diastolic shunting, which varied between 15% and 25% of the total, was noted in animals with or without changes in conduction pattern. The sequence of ventricular activation was an important factor in controlling systolic shunting and may be an important factor in the distribution of myocardial work.


Key Words: electromagnetic flow transducer • Congenital heart disease • Fick method • diastolic shunting • cannulating flow transducer • ventricular shunts

Submitted on July 9, 1969
Accepted on October 5, 1970