Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation Research
Search: search_blue_button Advanced Search
Circulation Research. 1968;22:633-638

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by TOCKER, W. A.
Right arrow Articles by HOFF, H. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by TOCKER, W. A.
Right arrow Articles by HOFF, H. E.
(Circulation Research. 1968;22:633.)
© 1968 American Heart Association, Inc.


Defibrillation without A-V Block Using Capacitor Discharge with Added Inductance

WILLIS A. TOCKER B.S.1, LESLIE A. GEDDES M.E., Ph.D.1, HEBBEL E. HOFF M.D., Ph.D.1

1 Department of Physiology, Baylor University College of Medicine, 1200 Moursund Avenue, Houston, Texas 77025

Two hundred and seventy-two defibrillations of the ventricles of 17 dogs by capacitor discharge applied directly to the heart were accompanied by A-V block lasting up to 78 seconds. A range of 150 to 475 volts was employed using a 40 microfarad condenser. The duration of the block was proportional to the energy employed for defibrillation. With the minimum energy of 1.8 watt-sec that produced 100% defibrillation in all trials, A-V block was present in 14 of the 17 animals (average duration of A-V block varying from 3 to 18 seconds). That the A-V block is not vagal in origin was demonstrated by atropinization and vagotomy of the animals. Prolongation of the period of fibrillation up to 15 seconds was found not to be a factor in determining the duration of A-V block. Defibrillation with the same energy levels but with the inclusion of an 0.29 henry inductance abolished the A-V block in 115 defibrillations in the same 17 animals. The current waveform measured without inductance was of the capacitor discharge type (unidirectional and exponentially decaying); with the inductance in the circuit the current waveform was a highly damped sinusoidal alternating current consisting of slightly more than two full cycles of about 40 Hz.


Key Words: direct defibrillation • arrhythmia • atropine • anoxia • dog