Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation Research
Search: search_blue_button Advanced Search
Circulation Research. 1968;22:251-261

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by HYMAN, C.
Right arrow Articles by WONG, W. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by HYMAN, C.
Right arrow Articles by WONG, W. H.
(Circulation Research. 1968;22:251.)
© 1968 American Heart Association, Inc.


Capillary Filtration Coefficient in the Extremities of Man in High Environmental Temperatures

CHESTER HYMAN Ph.D.1 W. H. WONG M.D.1

1 University of Southern California School of Medicine, Department of Medicine, Section of Dermatology, Los Angeles, California 90033

The capillary filtration coefficient was measured in human extremities by a simplified technique using the capacitance plethysmograph. The method was validated in terms of consistency of values obtained on the same individual at various times, the correspondence between values obtained on a group of normal persons, and the agreement between values reported here and those of earlier workers made under corresponding environmental conditions and duration of measurement after venous occlusion. The technique was used to evaluate the change in capillary filtration coefficient in the calves of subjects when ambient temperature was increased from 20° to 35°C. Corresponding measurements of total blood flow in this segment and determinations of the clearance of iodide ion from pretibial intradermal depots were made in both environments. Cutaneous blood flow increased by almost 170% and the capillary filtration coefficient by about 40%, whereas the clearance did not change. It is concluded that neither the capillary filtration coefficient nor the clearance of isotopes from tissue depots has been established as a valid measure of capillary surface area. The possibility that during venous occlusion, fluid accumulated primarily in the subcutaneous tissues of the extremity is suggested and discussed.


Key Words: plethysmograph • thermoregulation • tissue clearance • edema • exchange vessels • filtration area

Accepted on December 6, 1967




This article has been cited by other articles:


Home page
ANGIOLOGYHome page
G. Simon, J. A. Franciosa, and J. N. Cohn
Decreased Venous Distensibility in Essential Hypertension: Lack of Systemic Hemodynamic Correlates
Angiology, March 1, 1979; 30(3): 147 - 159.
[Abstract] [PDF]


Home page
Arch DermatolHome page
W. H. Wong, R. I. Freedman, S. F. Rabens, S. Schwartz, and N. E. Levan
Low Molecular Weight Dextran Therapy for Scleroderma: Effects of Dextran 40 on Blood Flow and Capillary Filtration Coefficient in Scleroderma
Arch Dermatol, September 1, 1974; 110(3): 419 - 422.
[Abstract] [PDF]