Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation Research
Search: search_blue_button Advanced Search
Circulation Research. 1966;19:206-213

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by NOBLE, M. I. M.
Right arrow Articles by GUZ, A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by NOBLE, M. I. M.
Right arrow Articles by GUZ, A.
(Circulation Research. 1966;19:206.)
© 1966 American Heart Association, Inc.


Effect of Changing Heart Rate on Cardiovascular Function in the Conscious Dog

MARK I. M. NOBLE Ph.D., B.Sc., M.B., B.S.,1, DIANA TRENCHORD B.Sc.,2, ABRAHAM GUZ M.B., B.S., M.R.C.P.2

1 Department of Medicine, Charing Cross Hospital Medical School, Fulham Hospital London, W.6, England
2 Department of Medicine, Charing Cross Hospital Medical School, Fulham Hospital, London, W.6, England

The effect of heart rate on the cardiovascular system of the conscious dog was studied by pacing the heart with an implanted right atrial electrode. Left ventricular outflow was measured by an electromagnetic flowmeter with a chronically implanted transducer on the ascending aorta. As heart rate increased, stroke volume fell, and this was linearly related to heart rate over the entire range studied. Peak flow rate and maximum acceleration decreased as heart rate increased, but the change was small compared with that in stroke volume. The decrease in stroke volume resulted principally from a loss of volume ejected in late systole. An increase in heart rate sometimes resulted in a rise of cardiac output, and when this occurred mean arterial pressure rose; when cardiac output did not increase, mean arterial pressure also remained unchanged. The data suggest that there is a pressure for the systemic circulation analogous to the "critical closing pressure" of peripheral vascular beds. It was shown that in these circumstances changes in calculated systemic resistance may not reflect any real alterations in the peripheral vascular beds.


Key Words: blood flow • cardiac output • blood pressure • stroke volume • atrial pacing • aortic flow acceleration • unanesthetized dogs

Accepted on December 21, 1965




This article has been cited by other articles:


Home page
Cardiovasc ResHome page
I. Vergroesen, D. Merkus, J. W.G.E van Teeffelen, J. Dankelman, J. A.E Spaan, H. B van Wezel, M. I.M Noble, and A. J Drake-Holland
Chronic cardiac denervation affects the speed of coronary vascular regulation
Cardiovasc Res, December 1, 1999; 44(3): 615 - 622.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
M. I. M. Noble, I. T. Gabe, D. Trenchard, and A. Guz
Blood Pressure and Flow in the Ascending Aorta of Conscious Dogs
Cardiovasc Res, January 1, 1967; 1(1): 9 - 20.
[Abstract] [PDF]